Judul : PRAKONSENTRASI DAN ANALISIS ION KADMIUM BERBASIS FLOW INJECTION ANALYSIS
Abstrak :

CD-imprinted polymers (Cd-IPs) have been synthesized and retensinya properties have been
studied for the pre concentration and analysis of cadmium concentration at the level of µ g L-
1berbasis technique of flow injection analysis (FIA). This procedure is based on the retention
of ions Cd (II) on Cd-IPs are synthesized. Retention cadmium ions can elution quantitatively
with a solution of nitric acid directly onto the nebulizer system for atomic absorption
spectrometer. The retention capacity of the Cd-IPs acquired for 20.10 mg g-1pada pH
optimum and shows a quick retention kinetics. Analytical parameters such as retention
capacity, the volume of the sample, the concentration and volume of eluen have been
evaluated to obtain a good analytical performance. The system being developed makes it
possible to analyze 15 samples per hour, with a limit of detection of the 8 µ g L-1. For the
concentration of 50 μg L-1 has obtained precision values expressed as percent relative
standard deviation of 1.6 (n = 5). A method of analysis that was developed has been used for
the determination of cadmium in river water samples Cidurian, West Java, Indonesia with
satisfactory results.
Key words: consentration, analyzing miniscule, cadmium, FIA

Tahun : 2018 Media Publikasi : Jurnal Nasional Blm Akreditasi
Kategori : Jurnal No/Vol/Tahun : 2 / 15 / 2015
ISSN/ISBN : 1411-9447
PTN/S : Pakuan Program Studi : KIMIA
Bibliography :

Almeida, J. A., Barreto, R. E., Novelli, L. B., Castro, F. J., and Moron, S. E.,“Oxidative Stress Biomarkers and Aggressive Behavior in Fish Exposed to Aquatic Cadmium Contamination”. Neotrop.Ichtyol., 2009, Vol 7, pp. 103-108.

 

47

Amran, M. B., Panggabean, A. S., Sulaeman, A. and Rusnadi, M,. “Preparation of a Chelating Resin and its Application as a Pre concentration System for Determination of Cadmium in River Water by Flow Injection Analysis”,Spring 2011, Int. J. Environ. Res., 5(2):531-536, ISSN: 1735-6865.

 

B. Welz, M. Sperling, “Atomic Absorption Spectrometry”, 3rd compl. rev. ed., Wiley-VCH, Weinheim, 1999.

Flora, S. J. S.,“Metal Poisoning: Treatment and Management”. Review Article. Al Ameen, J. Med. Sci, 2009,Vol 2, pp. 4-26.

Liu G., Freund M.S., New Approach for the Controlled Cross-Linking of Polyaniline: Synthesis and Characteization, 1997, Macromol., 30, p.5660.

Panahi, Ahmad., Homayon., Samadi Zadeh., Marjaneh., Tavangari., and Simin. 2012. Nickel Adsorption from Enviromental Samples by Ion Imprinted Aniline-Formaldehyde Polymer. Islamic Azad University and Toosi University of Technology. Tehran : Iran. Vol. 31, No. 3.

Patrick, L., “Toxic Metals and Anti- oxidants. Part II the Role of Anti-oxidant in Arsenic and Cadmium Toxicity – Toxic Metals part II”, 2003, Alternativer Medicine Review.

PyrzyÅ„ska, K. and SzelÄ…g, H.,“On-line Preconcentration system with FAAS detection for determination of cadmium”, Anal.Lett., 2001, 34(12), 2153–2158

Rao, P.T., Daniel, S, Gladis, J.M.,“Tailored Materials for Preconcentration or Separation of Metals by Ion-Imprinted Polymers for Solid-Phase Extraction (IIPSPE)”,Trends in Anal. Chem., 2004, 23 (1): 29- 35.

Sid Kalal, H, Hoveidi, H., Thagiof, M., Pakizevand, N., Almasian, M. R., and Firoozzare, M. A., “Pre-concentration and Determination of Platinum (IV) in Water Samples Using Chelating Resin by 

URL :

 

Document

 
back