Repository Universitas Pakuan

Detail Karya Ilmiah Dosen

Titik Penta Artiningsih

Judul : Kajian Penggunaan Ferro-cement untuk Retrofit Kolom Beton Bertulang dengan Variasi Tingkat Pembebanan
Abstrak :

Building collapse that occurred mostly caused by structure failure in containment earthquake load, especially column element. Factors that lead to the failure of the column, among others is column planning that does not calculate ductility or restraint, resulting decline of column performance. One way to improve column strength and ductility are to retrofit the column by wrapping columns using ferro-cement. Research aims to discover the increase amount of axial load capacity from concrete column that has been retrofitted using fine-mesh. Experimental tests carried out on seven short column specimen with a square cross-section sized 120x120 mm and 600 mm high. Column test object are given axial load concentric with variations in loading rate 60%, 70%, and 80% of the maximum axial load. Then, column is retrofitted by being covered with ferro-cement, after that column are given axial load up to collapse. From the test results, column are obtained increased capacity in axial load after being retrofitted in the amount of 34.96%, 28.17%, and 22.87% with variations loading rate in 60%, 70%, and 80%.

Tahun : 2017 Media Publikasi : Jurnal Nasional Terakreditasi B
Kategori : Jurnal No/Vol/Tahun : No. 3 / Vol. 14 / 2017
ISSN/ISBN : 2549-2918
PTN/S : Universitas Pakuan Program Studi : TEKNIK SIPIL
Bibliography :

  1. Adang Kristianto, Yosafat Aji Pranata, Jeremy Julian, Nico Tandy Susilo. (2015)., Studi Perbandingan Peningkatan Kapasitas Aksial Kolom Lingkaran Beton Bertulang yang Diberikan Perkuatan FRP dan Pen Binder, Prosiding Konferensi Nasional Teknik Sipil ke 9 (KoNTekS 9), Makasar.
  2. Al-Chaar, G. K., Lamb, G. E. (2002). Design of Fiber Reinforced Polymer for Seismic Rehabilitation of Infilled Concrete Structures, Engineer Research and Development Center, US Army Corps of Engineers.
  3. Dwisukmawati E., Tavio. (2008). Tegangan Regangan Beton Mutu Normal Segiempat dengan Fine Mesh, Prosiding Seminar Nasional Manajemen Teknologi VIII, Surabaya.
  4. El-Dakhakhni, W. W., Hamid, A. A., Elgaaly, M. (2004). ‘Seismic Retrofit of ConcreteMasonry-Infill Steel Frames with Glass Fiber Reinforced Polymer’, Journal of Structural Engineering, ASCE, vol. 130 no. 9, September, 2004
  5. Jonie Tanijaya, Sepry Rantesalu. (2008). ‘Perilaku Dinding Pengisi dengan Perkuatan Lapisan Glass Fiber Reinforced Polymer’, Jurnal Adiwidia, Universitas Kristen Indonesia Paulus, vol. 1 no. 1, edisi Maret 2008
  6. Johanes Januar Sudjati, Hastu Nugroho, Paska Garien Mahendra. (2013). Perkuatan Kolom Beton Bertulang dengan Glass Fiber Jacket untuk Meningkatkan Kapasitas Beban Aksial, Prosiding Konferensi Na- Artiningsih / Kajian Penggunaan Ferro-Cement .../ JTS, VoL. 14, No. 3, Oktober 2017, hlm 170–181 181 sional Teknik Sipil ke 7 (KoNTekS 7), Surakarta.
  7. Johanes Januar Sudjati, Randi Angriawan Tarigan, Ida Bagus Made Tresna. (2015). Perbaikan Kolom Beton Bertulang Menggunakan Glass Fiber Jacket dengan Variasi Tingkat Pembebanan, Prosiding Konferensi Nasional Teknik Sipil ke 9 (KoNTekS 9), Makasar.
  8. Teddy Boen & rekan. (2010). Cara Memperbaiki Bangunan Sederhana yang Rusak Akibat Gempa Bumi, Australia – Indonesia Facility for Disaster Reduction

URL : https://ojs.uajy.ac.id/index.php/jts/article/view/1981/1286

 

Document

 
back